One of the regular maintenance items for hydraulic disc brakes is the periodic brake fluid change, which is supposed to be done every two years. When changing the fluid, it is essential to loosen the bleeder plug on the brake caliper to bleed air from the brake hose and inside the caliper, but care must be taken to prevent the hose attached to the plug from coming loose. An effective solution for this task is an air bleeder hose with a lock that can be securely fastened to the plug tip.
Table of Contents
- 1 Whether or not air is allowed in the path when changing brake fluid
- 2 If the fluid & air bleed hose is disconnected from the bleeder plug, it's a big deal.
- 3 A convenient item that locks using the nub at the tip of the plug.
- 4 With the one-way valve, fluid can be changed without opening and closing the bleeder plug.
Whether or not air is allowed in the path when changing brake fluid
Disc brake fluid is characterized by a high boiling point that does not boil even at the high temperatures generated during braking. On the other hand, the fluid is highly hygroscopic, and even a small percentage of moisture can cause the boiling point to drop by 50°C or more, which can lead to vapour lock (fluid boils and bubbles are generated, causing the brakes to fail), so replacement is necessary. The brake fluid replacement process, which is generally performed every two years, consists of either injecting new fluid into the master cylinder, brake hoses, and calipers with the old fluid remaining in them, or removing and cleaning them before injecting fluid into them. If the fluid is changed regularly, the former method is fine. However, if the fluid has not been changed for a long period of time and has turned brown, it is better to disassemble and clean the master cylinder and calipers, since there is often sludge-like dirt inside the master cylinder and calipers. When injecting new fluid after disassembling and cleaning, the time and effort required to bleed air in the path must be taken into consideration. Whether the fluid is pumped in from the master cylinder side by repeatedly operating the brake lever or pedal, or from the caliper bleeder plug using a syringe, the final air bleeding operation is required to exhaust any air remaining in the master cylinder, caliper, banjo bolts, etc. Of course, air bleeding is also necessary when replacing the old fluid with new fluid from the master cylinder while adding new fluid while the old fluid remains in the route. However, assuming that the old fluid does not have air bites, the risk of air mixing with the new fluid when it is added without interruption is extremely small. From the standpoint of work efficiency, it is better to "add and replace" fluid without draining it before contamination accumulates inside the master cylinder and calipers, even if the fluid visible from the inspection window is clear. However, this does not apply when replacing fluid with replacement of parts due to damage to the master cylinder cup seal or caliper piston seal.
If the fluid & air bleed hose is disconnected from the bleeder plug, it's a big deal.

The risk of hose disconnection can be reduced by using a special adapter for the bleeder plug instead of a direct connection to the silicone hose. However, the flexibility and reduced tension of the rubber makes it easier to disconnect, so replace it when it hardens.
A convenient item that locks using the nub at the tip of the plug.

The brake bleeder hose set lock type is sold at Straight, a nationwide tool store. The set includes an adapter and one-way valve to attach to the bleeder plug, and the tip of the silicone hose is inserted into a plastic bottle or similar object.

The metal adapter has a shutter-like locking mechanism at the tip that secures the nubby end of the bleeder plug to prevent it from slipping out.

Once set on the bleeder plug, it cannot be easily removed by pulling on the hose. If the brake lever or pedal is operated with the plug loose without opening and closing it, fluid may drip out without being noticed for a while when the hose is disconnected, but this is a safeguard.
With the one-way valve, fluid can be changed without opening and closing the bleeder plug.

The one-way valve has a built-in spring and valve that opens when a certain amount of pressure is applied in the direction of the arrow on the body to allow fluid to flow through, and closes when the pressure is removed to prevent back-flow. This function allows air to be purged even when the bleeder plug is loosened.

When actually used, the hose is placed in a plastic bottle or similar container and looks like this. When replacing deteriorated fluid with new fluid without draining it, the fluid drained from the end of the hose is fed until it becomes clear. If the reservoir tank in the master cylinder is empty, air bites into the reservoir, so be careful to check the amount of fluid remaining.
- Point 1 - Brake fluid deteriorates over time and must be changed regularly.
- Point 2 - If the hose that attaches to the bleeder plug is disconnected during the fluid change operation, there is a risk of splashing fluid that can damage the paint.
- Point 3 - Use a locking adapter that does not disconnect from the bleeder plug. Use of a bleeder hose with a locking adapter that will not come off the bleeder plug will prevent unexpected problems.
Like this article